Predictors of Left Atrial Appendage Apex Spontaneous Echo Contrast in Patients with Valvular Atrial Fibrillation

张薇,钟明,张运,黎莉,葛志明,皮延生
DOI: https://doi.org/10.3760/j.issn:1004-4477.2004.05.002
2004-01-01
Abstract:Objective To investigate the independent factors associated with the apex of left atrial appendage(LAA) spontaneous echo contrast (SEC) in patients with valvular atrial fibrillation (VAF). Methods Seventeen normal subjects and 21 patients with VAF were included. Plasma fibrinogen (Fg),vov Willebrand factor (vWF),D-dimer (DD),P-selectin,thrombin-antithrombin complexes (TAT) and plasminogen activator inhibitor-1(PAI-1) were measured. The apex of LAA SEC was assessed quantitatively by integrated backscatter (IBS). LAA flow and pulmonary venous flow were detected by transesophageal echocardiography. Results Fg,vWF,DD,TAT and PAI-1 were increased significantly in patients with atrial fibrillation compared with control ( P 0.05 - 0.001 ). The apex of LAA IBS intensity was significantly increased [( 14.06 ± 5.75 )dB vs ( 9.18 ± 3.80 )dB,P 0.05 ] and the velocity of LAA and pulmonary venous flow were significantly decreased ( P 0.05 ~ 0.01 ) in patients with LAA thrombus compared with those without LAA thrombus. The apex of LAA IBS intensity correlated with TAT ( r = 0.72 , P = 0.0007 ),DD ( r = 0.57 ,P = 0.014 ),and PAI-1 ( r = 0.40 , P = 0.042 ). Multivariate analysis showed that increasing TAT was the independent correlate of LAA apex SEC ( P 0.05 ). Conclusions Hemostatic abnormalities are associated with LAA apex SEC and thrombus. Increasing TAT is the independent predictor of LAA apex SEC in patients with VAF.
What problem does this paper attempt to address?