Comparison of Methods for Current Sampling in SVPWM Inverter

GENG Hua,YU Ai,YANG Geng
DOI: https://doi.org/10.3969/j.issn.1000-100x.2005.06.046
IF: 5.967
2005-01-01
IEEE Transactions on Power Electronics
Abstract:In closed loop current control systems,such as VC (Vector control) or DTC (Direct Torque Control) drive system,the performance is influenced by the property of the current sampling.Harmonic components in the feedback cur-rent which is sampled by current sensor will generate torque ripples in the torque loop and degrade stability and control precision of the system.In this paper,three methods for current sampling of the closed loop current control systems sup-plied by SVPWM (Space Vector Pulse-width modulation) inverter are compared:current sampling asynchronous with the on-off cycle of PWM (Pulse Width Modulation) wave;current sampling at the start point of each PWM on-off cycle;cur-rent sampling at the midpoint of each PWM on-off cycle.Both the results of simulation and experiment indicate that sam-pling at the start point or midpoint of each on-off cycle can achieve an ideal fundamental current wave with few harmonic components.This method can help to implement a high-precise closed loop current control.Also it can be used in other dif-ferent systems supplied by PWM inverter with moderate or small capacity,fixed PWM on-off cycle and high carrier wave ratio,such as alternate asynchronous or synchronous drive systems,APF (Active Power Filter) etc.
What problem does this paper attempt to address?