Research on the Control of HCl during the Incineration of Sawdust in a Fixed Bed

蒋旭光,李香排,池涌,严建华
DOI: https://doi.org/10.3969/j.issn.1001-2060.2004.05.012
2004-01-01
Abstract:Through tube-furnace tests the dechlorination effectiveness of various dechlorinating agents was investigated. By comparing the dechlorination results of the one and the same dechlorinating agent under various operating conditions the optimum dechlorination conditions were determined. The results of tests indicate that the dechlorination efficiency of calcium-based absorbents is higher than that of magnesium-based absorbents. The optimum dechlorination conditions of CaO can be given as follows: combustion temperature 500°C-600 °C, residence time 5-15 min. At a high temperature section the dechlorination efficiency of CaO is reduced drastically due to the high-temperature hydrolysis of dechlorination product CaCl2.
What problem does this paper attempt to address?