Case Study on Technical Renovation and Upgrading of AAO Processes by MBBR Technology
Liang Qian,Sheng Li,Beiping He,Lu Zhou,Jing Gao,Shuo Wan
DOI: https://doi.org/10.15890/j.cnki.jsjs.2017.01.016
2017-01-01
Abstract:The existing wastewater treatment plant for removing nitrogen and phosphorus by traditional AAO process in Xi'an Province was modified and upgraded. This modification was conducted without requisition of land,no new reaction tanks,and no changes of the main structures and pipe network. On the premise of keeping the wastewater treatment plant in normal operation condition,and taking advantage of the existing treatment equipment fully,the moving bed bio-membrane reactor (MBBR)technology was applied into the anoxic and anaerobic tanks. Hydraulic retention time (HRT)of the anoxic tank was extended to improve nitrogen and phosphorus removal efficiencies,meanwhile,super fine grille was applied to remove suspended solids (SS). The results show that final TP,TN and SS of the effluent are 0. 32,8. 0,7 mg/L respectively,which meet A level requirement of Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB 18918—2002).