Modified Fault Tree Analysis for Reliability Analysis in Wastewater Treatment System

Rui GENG,Lu ZHOU
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2011.06.005
2011-01-01
Abstract:Considering the characteristics of wastewater treatment projects,risk significance analysis and expert knowledge were integrated into conventional fault tree analysis(FTA),and a modified FTA method applicable to wastewater treatment system was developed.Taking total nitrogen concentration in an A2O wastewater treatment system as control object,according to the characteristics of A2O wastewater treatment process,the application of modified FTA method to reliability analysis of wastewater treatment system was analyzed.The FTA diagram with effluent limit violation for TN as top event was established,and the weak points of the system were identified based on the risk analysis model.The case analysis shows that the conclusions from the modified risk significance evaluation are consistent with the practical operation well,indicating that the modified FTA method is a good tool to guide the reliable operation of wastewater treatment system.
What problem does this paper attempt to address?