Experiment on Temperature Protection of Sleeve in Surge Line Nozzle of Pressurizer

卢冬华,王海军,陈听宽,毛庆,张毅雄
DOI: https://doi.org/10.3969/j.issn.0258-0926.2002.01.020
2002-01-01
Abstract:Simulative experiment focused on transient temperature is performed on a5:1model of surge line nozzle,with sealed sleeve or unsealed sleeve,of pressurizer in PWR,under inlet and outlet flow condition.The range of Re is4500~750000.The conclusion is as follows:sealed sleeve can ef-fectively protect surge line nozzle from thermal shock and thermal fatigue;Sealed sleeve has better protection than unsealed sleeve;at low flow rate unsealed sleeve has some protection from temperature,but it loses its protection at high flow rate.