Abstract:The local near wall fluid temperature and heat transfer coefficient distribution in three different areas were measured for T-junction with and without thermal sleeve where jet injected vertically down to the main flow. Flows with velocity ratio between 0.01 and 1.5 were measured. The diameter ratio of jet pipe to main pipe is 0.16. It was found at that downstream of the jet the thermal sleeve has little effect on heat transfer. At the inlet of the jet and inside the jet tube, the thermal sleeve distinctly affect heat transfer coefficient and near wall fluid temperature. The thermal sleeve’s effect is more marked when the velocity ratio becomes larger.