Multiplication characteristics of a gas-cooled ADS with fast-thermal coupling configuration

Litao Wang,Ganglin Yu,Shifei Shen,Rui Zhou
DOI: https://doi.org/10.1016/j.nucengdes.2018.09.028
IF: 1.7
2018-01-01
Nuclear Engineering and Design
Abstract:•A new scheme of gas-cooled subcritical core is designed and optimized.•The Keff and the Ks may differ considerably for the fast-thermal coupling ADS.•With the same Keff, the Ks of subcritical core is different for similar schemes.•When the Keff is 0.98, the Ks increases with the decrease of the amount of MAs.•The central reflector has the significant impact on the Ks when the Keff is fixed.
What problem does this paper attempt to address?