Accurate evaluation of critical flaw size in structural ceramics via femtosecond laser

Anzhe Wang,Bin Du,Ping Hu,Xinghong Zhang
DOI: https://doi.org/10.1016/j.ceramint.2018.09.102
IF: 5.532
2018-01-01
Ceramics International
Abstract:Critical flaw size of structural ceramics is generally less than 100 mu m and is therefore too small to be reliably evaluated. In this study, micro-sized flaws (as small as 10 mu m) were introduced via femtosecond laser for the first time, and the critical flaw sizes of ZrB2 and ZrB2-SiC-Graphite ceramics (12.9 mu m and 36.1 mu m, respectively) were accurately evaluated by linear extrapolation in double logarithmic coordinates. The critical flaw sizes calculated from the indentation fracture toughness (14.3 mu m and 34.3 mu m for ZrB2 and ZrB2-SiC-Graphite ceramics, respectively) agreed well with the experimental results, while significant overestimation would occur by using fracture toughness values measured by means of single-edge notched beam, single-edge V-notched beam and single-edge precracked beam methods, which was mainly due to the fact that the notches in these three tests had the depth scale nearly two orders of magnitude higher than those of the inherent flaws.
What problem does this paper attempt to address?