Error Testing and Compensation of an Inductosyn-Based Angular Measurement System

LI Haixia,ZHANG Rong,HAN Fengtian
DOI: https://doi.org/10.16511/j.cnki.qhdxxb.2016.22.020
2016-01-01
Abstract:Installation and calibration difficulties restrict the use of circular gratings to improve the precision of practical high-precise inductosyn-based angular measurement systems through angle-error sampling and compensation.The study analyzes appropriate solutions of sparse error sampling and compensation methods for this problem.The error characteristics of inductosyn-based angular measurement systems are analyzed to compensate for the subdivision error caused by the existing zero-point error and other subdivision errors to get the overall zero-point error with a prism.An error compensation method is then given using sparse sampling data.Tests show that the precision of an angular measurement system is improved by this method from a peak to peak error of 11.7″ to 2.9″.The method accurately identifies the zero point error and provides full-range error compensation with sparse sampling data for an inductosyn-based angular measurement system.
What problem does this paper attempt to address?