Abstract:As the angle measuring error of fiber optic gyroscope increases cumulatively under the condition of long-term operation,a new error calibration method is proposed for fiber optic sensor.The method is based on the principle of optical triangulation distance measurement,using data acquired by two laser displacement sensors to realize the real-time angular measurement,and the experimental verification of the measurement system is carried out on the high-precision turntable.Experimental results show that the range of angle measurement can be up to ± 10°,while the error is about ±0.005° through compensating the error by least square fitting method,which provides the basis for exact estimate of angle measuring precision of gyro.The non-contact optical measurement method used has no damage to the sur face to be measured.