Design Parameter Optimization of a 126 Kv Horseshoe Type Axial Magnetic Field Vacuum Interrupter

Haomin Li,Zihan Wang,Yingsan Geng,Zhiyuan Liu,Yali Zhang,Fang Zhao
DOI: https://doi.org/10.1109/deiv.2016.7763955
2016-01-01
Abstract:The objective of this paper is to determine optimal contact parameters of a 126 kV horseshoe type axial magnetic field (AMF) vacuum interrupter. By a combination of three design methods, including design of experiment (DOE) method, finite elements method and statistical analysis method, the optimal AMF characteristics of the contacts were determined by single factor analysis and orthogonal regression analysis. Four optimized parameters of contacts were chosen as follows: Outer diameter of iron plate (d), the difference between outer and inner diameter of iron plate (s), height of iron plates group (h) and slot angle of iron plate (θ). Here, an effective area was defined as a region in which the axial magnetic flux density was higher than 80% of the maximum value. In addition, three indexes of AMF characteristics, which were axial magnetic flux density at current peak (B y ), width of major magnetic area (D) and phase shift time (t), were chosen as optimization objectives. The optimization determined contact parameters of d, s, h and θ as 90 mm, 55 mm, 15 mm and 70°, respectively. The optimized B y , D, and t are 717.53 mT, 26.07 mm and 0.81ms, respectively.
What problem does this paper attempt to address?