Optimization design of separators for removing solid particles from main steam pipeline of high-parameter steam turbine

Liu-xi Cai,Shun-sen Wang,Shangfang Cheng,Junfeng Xiao,Song Gao,Yuanyuan Li
DOI: https://doi.org/10.1016/j.applthermaleng.2016.09.146
IF: 6.4
2017-01-01
Applied Thermal Engineering
Abstract:•Particle rebound models were developed using high temperature test results.•ηp of 100μm particle can reach up to 78% under a small amount of transferring steam.•Qs equals to 0.25% is recognized as the optimum separation point.•Particle trap B with annulus inlet is the optimal one considering ηp and ΔP.•Effect of particle trap on the heat rate of thermal system is less than 0.15%.
What problem does this paper attempt to address?