Experimental Study of the Separation Performance of a Square Separator Assuming a Horizontal Heat Exchange Mode

王东,程乐鸣,周强,骆仲泱
DOI: https://doi.org/10.3969/j.issn.1001-2060.2003.03.003
2003-01-01
Abstract:An experimental study was conducted for the separation efficiency and separator resistance of a horizontal heat exchange mode-based square separator under different air speeds and inlet concentrations. The influence of operating conditions on separation performance was analyzed. To achieve an optimized design, the authors have carried out optimization tests with respect to various construction schemes. The test results indicate that a separator incorporating an exhaust pipe with a diameter and insertion length equal respectively to 1/3 and 1/15 of separation characteristic size will offer high efficiency and low resistance. For solid particles with a diameter greater than 100 μm the separation efficiency will be in excess of 90% and the resistance less than 1.5 kPa.
What problem does this paper attempt to address?