Modeling Dose-Rate On/over the Surface of Cylindrical Radio-Models Using Mont Carlo Methods

肖雪夫,张积运,王仲奇,黄清波,马国学,张家秋,王朝辉,望新兴,文富平,王军
DOI: https://doi.org/10.3760/cma.j.issn.0254-5098.2004.01.024
2004-01-01
Abstract:Objective To determine the dose-rates on/over the surface of 10 cylindrical radio-models,which belong to the Metrology Station of Radio-Geological Survey of CNNC. Methods The dose-rates on/over the surface of 10 cylindrical radio-models were modeled using the famous Monte Carlo code-MCNP.The dose-rates on/over the surface of 10 cylindrical radio-models were measured by a high gas pressurized ionization chamber dose-rate meter,respectively.The values of dose-rate modeled using MCNP code were compared with those obtained by us in the present experimental measurement,and with those obtatined by other workers previously.Some factors causing the discrepancy between the data obtained by us using MCNP code and the data obtained using other methods are discussed in this paper. Results The data of dose-rates on/over the surface of 10 cylindrical radio-models,obtained using MCNP code,were in good agreement with those obtained by other workers using the theoretical method.They were within the discrepancy of ±5% in general, and the maximum discrepancy was less than 10%. Conclusions As if each factor needed for the Monte Carlo code is correct,the dose-rates on/over the surface of cylindrical radio-models modeled using the Monte Carlo code are correct with an uncertainty of 3%. ;
What problem does this paper attempt to address?