Development and Properties of Reference Electrode for Electrochemical Corrosion in High Temperature and High Pressure Environment

任呈强,刘道新,白真权
DOI: https://doi.org/10.3969/j.issn.1001-1560.2004.04.013
2004-01-01
Abstract:High performance Ag/AgCl reference electrode had been made for in situ investigation of electrochemical corrosion under the conditions of high temperature and high pressure (HPHT) by optimizing of chlorinating process, improving of sealing structure and adopting of saturated KCl solution to overcome the instability of imported HPHT reference electrode. Thus the electrochemical system of autoclave is perfect to achieve the corrosion measurement in simulating oilfield downhole environments of HPHT. Comparing of the electrochemical results in situ and simulation of HPHT environments, it is confirmed that simulation test is unsuitable for discussion of corrosion behaviors and mechanisms of tube steel in HPHT oil and gas well.
What problem does this paper attempt to address?