Study on High Temperature Corrosion Resistance of Domestic Super 304H Heat Resistant Steel in Real Furnace

Hong XU,Zhiyuan LIANG,Jianliang DING,Qinxin ZHAO,Shixian XU
DOI: https://doi.org/10.14158/j.cnki.1001-3814.2017.24.015
2017-01-01
Abstract:The high temperature corrosion resistance of austenitic heat-resistant steel Super304H experimental tube in a real flue gas environment was investigated. The experiment tube was studied by XRD, SEM and EDS. The results show that the corrosion layer of the section is multilayered structure, containing outer layer, inner layer and permeable layer. Complex alkali metal composite sulfate corrosion reaction occurs in the outer layer. Oxidation reaction occurs in the inner layer. Oxidation and sulfuration reactions occur simultaneously in the permeable layer. The outer surface of the experimental tube generates exfoliation, and the exfoliation position locates at the interface of outer/inner corrosion layer, which is mainly related to the temperature fluctuation in running and different thermal expansion of outer/inner corrosion layers.
What problem does this paper attempt to address?