The study of radiation-carrying capacity of coated stents
江洪,黄从新,王洪如,漆曙辉,唐其柱,李庚山
DOI: https://doi.org/10.3969/j.issn.1004-8812.2001.02.019
2001-01-01
Abstract:Objective Recent study have shown that radioactive 32 P stenting is a potential solution for the prevention and treatment of restenosis, but the radiation-carrying capacity of stent is a difficult problem needing to study. Here it was reported that four coated stents were studied in order to investigate which one was the best to carry radioactive 32 P. Methods Four kinds of coated stents, plasma-coated stent, isinglass-coated stent, 32 P-coated stent, vein-coated stent were made, 6 for each kind, radioactive stents were washed in the slushing pipe with 90 mm?Hg pressure, the radioactivity was measured before washing and in 1, 4, 7, 14, 21 days after washing. In 4 canines two plasma-coated stents were implanted into the coronary artery respectively, the radioactivity of the stents was measured immediately and 1 day, 2 weeks, 7 weeks, 10 weeks after implantation. In 3 canines 1 vein-coated stent was implanted into the coronary artery respectively, and the radioactivity was measured in 1 month, 2 months, 3 months after implantation. Results In irrigation tests, the radioactivity of each kind of coated stents was 4.81, 4.32, 1.96, 4.82 μCi before washing, 0.33, 0.12, 0.01, 1.34 μCi in 21 days after washing respectively. In implantation tests, 8 plasma-coated stents were successfully implanted into 4 canines, its radioactivity during different times was 4.98, 1.71, 0.52, 0.09, 0.03 μCi respectively. Only one canine was successfully implanted one vein-coated stent. Conclusion The results suggest that radiation-carrying capacity is better in vein-coated stent and plasma proteins-coated stent, the plasma-coated stent could be made and implanted into coronary artery easily, its dosage is enough to inhibit restenosis of coronary artery angioplasty. Objective Recent study have shown that radioactive 32 P stenting is a potential solution for the prevention and treatment of restenosis, but the radiation-carrying capacity of stent is a difficult problem needing to study. Here it was reported that four coated stents were studied in order to investigate which one was the best to carry radioactive 32 P. Methods Four kinds of coated stents, plasma-coated stent, isinglass-coated stent, 32 P-coated stent, vein-coated stent were made, 6 for each kind, radioactive stents were washed in the slushing pipe with 90 mm?Hg pressure, the radioactivity was measured before washing and in 1, 4, 7, 14, 21 days after washing. In 4 canines two plasma-coated stents were implanted into the coronary artery respectively, the radioactivity of the stents was measured immediately and 1 day, 2 weeks, 7 weeks, 10 weeks after implantation. In 3 canines 1 vein-coated stent was implanted into the coronary artery respectively, and the radioactivity was measured in 1 month, 2 months, 3 months after implantation. Results In irrigation tests, the radioactivity of each kind of coated stents was 4.81, 4.32, 1.96, 4.82 μCi before washing, 0.33, 0.12, 0.01, 1.34 μCi in 21 days after washing respectively. In implantation tests, 8 plasma-coated stents were successfully implanted into 4 canines, its radioactivity during different times was 4.98, 1.71, 0.52, 0.09, 0.03 μCi respectively. Only one canine was successfully implanted one vein-coated stent. Conclusion The results suggest that radiation-carrying capacity is better in vein-coated stent and plasma proteins-coated stent, the plasma-coated stent could be made and implanted into coronary artery easily, its dosage is enough to inhibit restenosis of coronary artery angioplasty.