Study on the effect of the stent coated with endothelial progenitor cells CD34 antibody on the porcine coronary restenosis

张基昌,李淑梅,宋春莉,刘斌
DOI: https://doi.org/10.3969/j.issn.1005-9202.2009.04.004
2009-01-01
Abstract:Objective To investigate whether the stent coated with bio-degradable macromolecule carrying endothelial progenitor cells(EPCs) CD34 antibody can prevent restenosis in the porcine coronary after percutaneous stent implantation.Methods Bio-degradable macromolecule polyethyleneglycol-polylactic acid-polyglutamic acid(PLA-PEG-PGL) was used as the carrier,and EPCs CD34 antibody eluting stent was made by N-succinimidyl 3-(2-pyridyldithio) propionate(SPDP).18 swines were randomly assigned into paclitaxel eluting stent,CD34 antibody stent,and bare metal stent groups(n=6).Paclitaxel eluting,CD34 antibody,and stainless steel bare metal stents were embedded into the injured coronary arteries of the swine respectively.After 4 weeks,all swines were killed and coronary arteries of stent section were obtained to observe the pathological changes and analyze lumen area,intimal hyperplasia area and the percent of stenosis area by computer graphic technology.Results The intimal hyperplasia areas of CD34 antibody stent and paclitaxel eluting stent groups were all smaller than that of bare metal stent group(all P<0.05),and there was no statistical difference between the paclitaxel eluting stent and CD34 antibody stent group(P>0.05).Conclusions The stent coated with bio-degradable macromolecule carrying endothelial progenitor cells(EPCs) CD34 antibody can obviously reduce restenosis by accelerating vascular endothelial repairing after stent implantation.
What problem does this paper attempt to address?