Effects of Preload Voltage on Performance of Force-Rebalance Micro Silicon Accelerometer

李疆,董景新,刘云峰,吴天准
DOI: https://doi.org/10.3969/j.issn.1000-9787.2004.08.013
2004-01-01
Abstract:The voltage range on the forcer of a force-rebalance accelerometer in some experiments is different from the one used in traditional calculations.In order to find out the effects of preload voltage on the performance of the accelerometer,the transfer function of the forcer,the equation of the negative electrostatic stiffness and other equations are deduced under the experiment voltage.The results of the parameters analysis show that the sensitiveity,span and resolution of the accelerometer are directly affected by the preload voltage,but the nonlinearity is independent of the preload voltage.Based on all the factors shown above,a method is provided to select the preload voltage according to the requirements of different applications,and this method is validated to be correct by the experiment.
What problem does this paper attempt to address?