Study on the Factor of the Time in Intravenous Contrast-Enhancement

刘远健,冯晓源,刘鹏程,高文清,赵艳,陈在中,邹立秋,江国银
DOI: https://doi.org/10.3969/j.issn.1000-0313.2003.06.024
2003-01-01
Abstract:Objective:To investigate the process of contrast enhancement with a factor of time for clinical reference of an adequate method and scanning period after intravenous injection of contrast medium.Methods:A total of 50 cases with enhanced scans were studied,including 31 cases with EBCT scans and 19 cases with spiral CT scans respectively.The age of these examinee were 21~73 years old (an average of 40.8±10.9).The dosage of contrast medium was 30~40ml at an injection rate of 5~8ml/s depending on person′s body weight.The characteristic measurements according to enhancement curve of the aorta were recorded as following parameters:injecting time (IT),starting point of ascending (SP),ascending time (AT),ascending Hounsfield units (A HU),peak point time (PP) and peak Hounsfield units (P HU).Results:The average IT was about 5s,SP 9s,AT 5.84s,A HU 183.7,PP 14.97 and P HU 235.3.Conclusion:The process of contrast enhancement in vivo varies as the shape of r curve.The ascending time (AT) of the curve is positively proportional to the injection time (IT),and the peak point time (PP) of the curve appeares roughly later if the injection time is longer.
What problem does this paper attempt to address?