Coronary angiography by 64-slice CT: optimization of contrast medium injection

Jian-xing QIU,Ji-chen WANG,Jian LIU,Li GAO,Xiao-wei SUN,Yi-sheng WANG,Xue-xiang JIANG
DOI: https://doi.org/10.3321/j.issn:1003-3289.2006.10.005
2006-01-01
Abstract:Objective: To investigate the optimum contrast medium injection plan of coronary angiography by 64-slice CT. Methods: Thirty consecutive patients undergoing coronary angiography by 64-slice CT were divided into three groups, namely group A, group B1 and group B2, each group included 10 patients. Patients in group A were less than 70 kg, patients in group B1 and group B2 were heavier than 70 kg. Group A and group B1 were injected 50 ml contrast medium with speed of 4.5 ml/s. Group B2 was injected 70 ml contrast medium with speed of 5 ml/s. The enhanced effect of three groups of patient in aorta, the trunk and branch of coronary artery were compared. Results: The difference of enhancement in every vessel between group A and group B2 was not significant. Enhancement in partial vessel in group B1 was significantly less than in group B2. Conclusion: The optimum contrast medium injection plan of coronary angiography by 64-slice CT was feasible.
What problem does this paper attempt to address?