Application of Optimized Contrast Agent Injection in CT Pulmonary Angiography

崔晨,刘建新,王霄英,杨俊哲,郭小超
DOI: https://doi.org/10.3969/j.issn.1000-0313.2013.05.004
2013-01-01
Abstract:Objective:To explore the feasibility of optimized three-phases contrast agent injection in CT pulmonary angiography(CTPA) for reducing the amount of contrast agent and improving the examination success rate.Methods:Sixty-three patients(from Apr.2011 to Aug.2011) undergone CTPA were included in this study and randomly divided into two groups.Group A:three-phases injection,30 patients.Phase Ⅰ:10% contrast agent and 90% saline,5mL/s,25mL;phase Ⅱ:contrast agent 5mL/s,total amount equal to body weight(kg)× 0.2~2.5;Phase Ⅲ:saline,5mL/s,20mL.Group B dual-phases injection,33 patients.Phase I:contrast agent 20mL;phase Ⅱ:saline 30mL.Injection rate was 5.5mL/s.CT value of pulmonary trunk(PT),left/right pulmonary artery(L/RPA),lobar/segmental/subsegmental pulmonary artery,superior vena cava(SVC) at pulmonary artery bifurcation level,main pulmonary vein(MPV) and ascending aorta(AS) were measured.The amount of contrast agents of the two groups were compared.Results:There was significant difference in CT value of PT,SVC and AS of the two groups(P0.05).The amount of contrast agents were 10.73mL in group A versus 20mL in group B,representing a decrease of 46%.Conclusion:Compared with traditional dual-phases injection,optimized three-phases contrast agent injection can improve the success rate of CTPA examination and reduce the amount of contrast agent.
What problem does this paper attempt to address?