Simulation on the Structure Effects of Hollow Fiber Membrane on CO 2 Removal from Flue Gas

YAN Yun-fei,ZHANG Zhi-en,YAN Shui-ping,JU Shun-xiang,ZHANG Li,ZHANG Ji-guang
DOI: https://doi.org/10.3969/j.issn.1003-9015.2015.02.032
2015-01-01
Abstract:Compared with traditional CO2 separation methods, the absorption of CO2 in flue gas with hollow fiber membrane is a clean and efficient decarbonization technology. This paper used the finite element method and established a 2D model of hydrophobic hollow fiber membrane for the removal of CO2 in flue gas. The CO2-removal efficiency was investigated from the membrane diameter, thickness, porosity, tortuosity, the number of fibers, membrane column diameter and length. The modeling results are consistent with the experimental values. The results show that the sequence of absorption efficiency of four absorbents is EDA>MEA>DEA>AMP. Decreasing the tortuosity, thickness, and column diameter, or increasing the porosity, fiber diameter, and membrane length, is beneficial to the membrane absorption of CO2under the conditions of 0.1 m·s–1liquid velocity, 0.211 m·s–1gas velocity and 0.1 MPa operation pressure.
What problem does this paper attempt to address?