Experimental study on bearing capacity and seismic behavior of large- span two- storied Vierendeel truss transfer structure

傅传国,蒋永生,梁书亭
DOI: https://doi.org/10.3321/j.issn:1000-6869.2004.01.005
2004-01-01
Abstract:Regarding actual engineering as the back ground, two 1/8 scale large span two storied Vierendeel truss transfer structure models were tested. In which one of them was common reinforced concrete structure, and the other used prestressed steel reinforced concrete(PSRC) in bottom chord of the transfer structure. This paper introduced and analyzed the bearing capacity , seismic behavior and failure mechanism of the two models under vertical and quasi dynamic loads. The test results indicated that the transfer structure models have good performance of integrated work and satisfactory bearing capacity,and can realize ductile failure mode. The model with partial steel reinforced concrete expresses the performance more superior. The test results also showed that the prestressing force can efficiently improve the rigidity and crack resistance of the transfer structure.
What problem does this paper attempt to address?