Stress Analysis of HTR-10 Steam Generator Heat Exchanging Tubes

董建令,张晓航,殷德健,傅激扬
DOI: https://doi.org/10.3969/j.issn.0258-0926.2001.05.012
2001-01-01
Abstract:Steam Generator(SG)heat exchanging tubes of 10MW High Temperature Gas Cooled Re-actor(HTR-10)are protective screens between the p rimary loop of helium with radioactivity and the sec-ondary loop of feeding water and stea m without radioactivity.Water and s team will enter into the primary loop when rupture of the heat exchanging tubes occurs,which lead to incre ase of the primary loop pressure and discharge of radioactive materials.Therefore it is important to guarantee the integrity of the tubes.The tube structure is spiral tube with sm all bending radius,which make it imp ossible to test with volumetric in-service detection.For such kind of spiral tube,using LBB concept to g uarantee the integrity of the tubes i s an important option.This paper conducts stress analysis and calculatio n of HTR-10SG heat exchanging tubes using the FEM code of piping str ess analysis,PIPESTRESS.The maxim um stress and the dangerous positions are obtained.
What problem does this paper attempt to address?