THE EVALUATION OF CARDIAC FUNCTION IN PATIENTS WITH CORONARY HEART DISEASE BY RADIONUCLIDE VENTRICULOGRAPHY

WU Shuyan,WANG Jiucheng,LIN Jinghui
DOI: https://doi.org/10.3321/j.issn:1671-167x.1998.02.024
1998-01-01
Abstract:Objective:To evaluate the cardiac function in patients with coronary heart disease. Methods: Radionuclide ventriculography was used to measure the systolic and diastolic functions of the heart in 90 patients with coronary heart disease. Results:In the group of patients with angina pectoris the diastolic function was abnormal. In the group of patients with myocardial infarction both systolic and diastolic functions were impaired in the early stage, which were improved thereafter. In the patients with inferior wall infarction the systolic function returned to normal, but the diastolic function remained lower. In patients with anterior wall myocardial infarction, the systolic and diastolic functions of the heart were improved slowly after myocardial infarction. Conclusion:In different kinds of coronary heart disease, the cardiac functions were damaged in different ways, the diastolic function was impaired earlier than the systolic function. But the diastolic function was improved later than the systolic function.