Treatment of dilute Ni2+-containing wastewater by electrodeionization with bipolar membrane:Precipitation

SHANG Guang-hao,ZHANG Gui-qing,GAO Cong-jie
DOI: https://doi.org/10.19476/j.ysxb.1004.0609.2014.10.033
2014-01-01
The Chinese Journal of Nonferrous Metals
Abstract:The generation and avoidance of Ni(OH) 2 precipitation during the treatment of the simulated dilute Ni2+-containing wastewater were investigated by electrodeionization with bipolar membrane. The results show that, the current density distribution along the height of EDI-BP stack is uneven. The reason of Ni(OH)2 precipitates on the surface of anion membrane near the outlet of feed in concentrate compartment is high local concentration of Ni2+ and OH-. Ni(OH)2 precipitating on the surface of the cation membrane near the inlet of first dilute compartment due to the splitting of water. By lowering the pH value of concentrate and feed, the generation of Ni(OH)2 precipitate can be avoided. Under the condition of Ni2+ concentration, flowrate, pH value of feed, pH value of concentration and the current density are 30 mg/L, 0.317 cm/s, 2.77, 1.18 and 9.5 mA/cm2, respectively, the concentration experiment carries stably for 285 h. The diluate is Ni2+-free at the conductivity of 1.5 μS/cm, and the concentration of Ni2+ in concentrate reaches 2.7 g/L which is 90 times of that in feed.