Determining Ba Isotopes of Barite Using the Na2CO3 Exchange Reaction and Double-Spike Method by MC-ICP-MS
Lan-Lan Tian,Zhen Zeng,Xiao-Yun Nan,Hui-Min Yu,Fang Huang
DOI: https://doi.org/10.1039/c9ja00064j
2019-01-01
Journal of Analytical Atomic Spectrometry
Abstract:This study presents a practical method for high precision Ba isotope measurement of barite using the Na2CO3 exchange reaction and Ba-135-Ba-136 double-spike method by MC-ICP-MS. The effects of matrices and conditions of the exchange reaction were rigorously examined. The precision and accuracy of this method were tested by measurement of a synthetic barite standard prepared by reacting Ba(NO3)(2) with Na2SO4. The delta Ba-137/134 of the synthetic barite is 0.06 +/- 0.03 parts per thousand (2SD, n = 16) relative to SRM3104a, which is well consistent with the recommended value (0.07 +/- 0.04 parts per thousand, 2SD, n = 769). The robustness of this method was further assessed by replicate analyses of six barite reference materials, which cover a large range of BaSO4 contents from 18.87 wt% to nearly 100 wt%. The delta Ba-137/134 of pure barite international standard NBS127 is -0.21 +/- 0.03 parts per thousand (2SD, n = 20); the delta Ba-137/134 of natural standards GBW07811, 07 812, 07 814, 07 815 and 07 816 is -0.06 +/- 0.05 parts per thousand (2SD, n = 12), 0.24 +/- 0.05 parts per thousand (2SD, n = 48), -0.02 +/- 0.02 parts per thousand (2SD, n = 10), -0.05 +/- 0.04 parts per thousand (2SD, n = 18), and -0.01 +/- 0.05 parts per thousand (2SD, n = 20), respectively. Based on repeated analyses of these standards, the long-term external precision of delta Ba-137/134 is better than 0.05 parts per thousand (2SD), much smaller than the variation in these barite standards (up to 0.45 parts per thousand), revealing the large Ba isotope fractionation in natural barites.