Study Design and Application on the Attemperator and the Depressurizer of the Gas By-Pass in Jiawang PFBC Pilot Plant

肖军,章名耀,蔡宁生
DOI: https://doi.org/10.3969/j.issn.1009-2889.2001.03.009
2001-01-01
Abstract:In Jiawang PFBC pilot plant,the gas bypass is a safety pass while the system starts up,or the gas-turbine has malfunction and reduced load.The attemperator and the depressurizer are the key equipments of the bypass.In this paper,the venturi spray attemperator and the depressurizer with minute orifices are designed and applied novelly to discharge the high-temperature and high-pressure gas with particle reliably.The practical operation of the pilot plant shows this unit is compact,economic,and reliable.