Evaluation of Work of Breathing As a Weaning Index in Mechanically Ventilated Pathents with Chronic Obstructive Pulmonary Disease

李敏,黄绍光,汤葳,邓伟吾
DOI: https://doi.org/10.3760/j.issn:1671-0282.2003.12.016
2003-01-01
Abstract:Objective To evaluate work of breathing (WOBp) as a weaning index in mechanically ventilaed patients with COPD.Methods Using bed-side pulmonary mornitor(Bicore-cp100),work of breathing in 27 patients with respiratory failure were observed under different periods of ventilation and after weaning ventilation,and in 12 patients during stable period of COPD.Sensitivity and sepcificity different predictive value in weaning were analyzed.Results In 21 patients with successful weaning,the mean value of WOBp was (1 19±0 26)J/L,while in 6 patients without succeuful weaning the mean value was (1 65±0 39)J/L,significantly higher ( P 0 01) than that in the group with successful weaning and control group(1 14±0 28)J/L.Continuous observation in 14 patients during exacerbation and after weaning showed a decrease in value from (2 07±0 62)J/L,to (1 13±0 3)J/L( P 0 01).The sensitivity was only 19% when the weaning standard was at the routine level with work of breathing≤0 8 J/L.Th sensitivity was 71% and specificity was 100% when the weaning standard was at work of breathing1 1 J/L level.Conclusion The routine weaning standard is not suitable for the COPD patients because their basic work of breating value is high.It is suggested that the weanign standard for COPD patients might be properly enhanced.If the value of work of breathing1 1 J/L,the sensitivity to predicting weaning can be increased.Continuous observation of work of breathing is helpful for predcting weaning.
What problem does this paper attempt to address?