The Anterior Fixation of Odontoid Process Fracture by Single Canulated Compressive Screw

刘少喻,梁春祥,陈柏龄,李佛保,龙厚清,陈立言,于滨生,韩国伟
DOI: https://doi.org/10.3760/j.issn:0253-2352.2003.10.005
2003-01-01
Abstract:Objective To compare the clinical effectiveness of fixations of odontoid process fractures preliminarily with anterior single one-threaded and double-threaded canulated compressive screws. Methods From April 1997 to April 2003, 20 cases of odontoid process fracture were fixed internally by anterior approach with single canulated compressive screws. The patients were all males with the age of 18 to 56 years. All the patients had a history of head trauma prior to fracture. The interval from injury to diagnosis was averagely 3.7 days ranging from 0 to 8 days. All of the patients complained of pain in posterior part of neck, and 6 cases with mild numbness of both hands. Of these cases, 16 were Anderson type Ⅱ and 4 were shallow type Ⅲ. 18 fractures were dislocated less than 25%, while 3 patients were associated with unilateral intervertebral joint avulsed fracture. As the diagnosis were established, skull traction were installed at once. Only after the fracture was reduced and became stable more than 5 days confirmed by bedside X-ray examination, could the operation be performed. 12 cases were fixed with one-threaded canulated compressive screws, and the other 8 with double-threaded canulated compressive screws. The operation time, blood loss, fracture healing and the cervical motion function were evaluated respectively. Results The operation times of the two groups were from 110 to 150 minutes (average, 125 minutes). The blood losses during operation were from 20 to 100 ml (average, 42 ml). There was no operative complication with wound healed well in the two groups. The follow-up were from 2 to 72 months with an average of 14.7 months. The fractures of 19 cases healed in an average 12.7 weeks, one of them was delayed union lasted to 17 weeks. The cervical motion function of 17 cases recovered completely after fracture union. The 3 cases associated with intervertebral joint avulsed fractures reminded mild limitation in cervical rotation by 20%. There was no difference between the two kinds of screws regarding to the operation time, blood loss, fracture healing, and cervical motion. Conclusion The effects of internal fixations of the odontoid process fractures are satisfactory either with the single one-threaded canulated compressive screw or the single double-threaded canulated compressive screw.
What problem does this paper attempt to address?