Anterior screw fixation for odontoid fracture by using ISO-3D computer assistant navigation

ZHANG Bo,TIAN Wei,WANG Yong-qing,LIU Bo,LI Qin,YUAN Qiang
DOI: https://doi.org/10.3969/j.issn.1002-266X.2010.28.010
2010-01-01
Abstract:Objective To investigate the feasibility and results of anterior odontoid screw fixation by using ISO-3D computer assistant navigation.Methods There were 27 patients with type Ⅱ or shallow type Ⅲ dens fracture underwent anterior odontoid screw fixation assisted by using ISO-3D computer assistant navigation.The patients' clinical outcomes within-and after-operation were evaluated.Results All patients underwent the operation successfully with no complication occurred.The operation time was 70 to 180 minutes,with an average of 110 minutes.The blood-losing was 30 to 100 ml,with an average of 56 ml.The cut healed by first intention and no infection occurred.On 1-year-follow-up,bony union was observed in 24 patients meanwhile fracture line was still visible in 3 patients.The screw fixation remains stable and no upper cervical unstable or inner-fixation failure occurred.The neck degree in rotation on each side was 40° to 70°,with an average of 51°.No related neural symptom occurred or worsen.Conclusion The application of ISO-3D computer assistant navigation in anterior odontoid screw fixation improve the accuracy and security of the operation,decrease the radiological dose on operator and did not increase the operation-time significantly,which indicates a better advantage.