High-performance Liquid Chromatographic Method for the Determination of Ultratrace Amounts of Iron(ii) in Aerosols, Rainwater, and Seawater
Z YI,GS ZHUANG,PR BROWN,RA DUCE
DOI: https://doi.org/10.1021/ac00046a028
IF: 7.4
1992-01-01
Analytical Chemistry
Abstract:A reversed-phase high performance liquid chromatography method was developed to determine concentrations of iron(II) In Chinese loess, aerosols, rainwater, and seawater. This method was isocratic, rapid, sensitive, and reproducible. Iron(II) form a stable complex ion with the reagent ferrozine, [Fe(FZ)3]2+ in a pH range of 4-10. By measuring the absorbance of [Fe(FZ)3]2+ at 254 nm, iron(II) concentrations wore determined. [Fe(FZ)3]2+ was separated from ferrozine and was detected in 6 min. Reversed-phase C18 solid-phase extraction cartridges, which were used for the sample preparation, concentrated the [Fe(FZ)3]2+ and increased sensitivity of the analysis. A detection limit of 0.1 nM Fe(II) was obtained. Retention time, addition of known amount of standard, and peak area ratios were used for peak identification of [Fe(FZ)3]2+. There was no interference from Fe(III), Ni(II), Co(II), and Cu(I). The recovery of 10(-8)-10(-10) M [Fe(FZ)3]2+ using the preconcentration step was in the range of 92-99%. The Fe(II) concentration in remote marine aerosols has been determined for the first time by using this new method.