A Modified Approach to Actively Remove High Viscosity Silicone Oil Through 23-Gauge Cannula

Zong-Ming Song,Xu-Ting Hu,Lei Wang,Zhi-Xiang Hu,Pei-Quan Zhao,Ding Chen
DOI: https://doi.org/10.18240/ijo.2016.09.10
IF: 1.645
2016-01-01
International Journal of Ophthalmology
Abstract:AIMTo report a simple approach to actively remove high viscosity silicone oil through a 23-gauge cannula via pars plana.METHODSForty-eight eyes of 48 patients underwent silicone oil (5700 centistokes) removal (SOR) were enrolled. A section of blood transfusion set was prepared to connect a standard 23-gauge cannula and vitrectomy machine. Silicone oil was removed with suction of 500-mm Hg vacuum through the cannula. Main outcome measures were SOR duration, number of sutured sites, intraocular pressure (IOP), best-corrected visual acuity (BCVA), and complications.RESULTSSilicone oil was successfully removed in all cases. The mean SOR time was 5.70±0.85min. Nine eyes (18.75%) needed suture partial sclerotomies. No intraoperative complications were noted. Transient hypotony (≤8 mm Hg) was seen in 3 eyes (6.25%) on postoperative day 1, but all resolved within 1wk. Retinal reattachment was achieved in all cases and no other postoperative complications were noted during 3-month following-up. BCVA at the final visit improved or stabilized in all patients comparing to the preoperative level.CONCLUSIONActive removal of high viscosity silicone oil through a 23-gauge instrument cannula jointed with blood transfusion set is a practical and reliable technique when considering two sides of efficacy and safety.
What problem does this paper attempt to address?