Changes in Visual Acuity, Axial Length, and Refraction after Removal of Intraocular Silicone Oil Following Retinal Reattachment Surgery in Chinese Patients: an Open-Label, Prospective Study
An-Huai Yang,Wei Jin,Yi-Qiao Xing
DOI: https://doi.org/10.1016/j.curtheres.2009.06.002
2009-01-01
Current Therapeutic Research
Abstract:BACKGROUND: As a vitreous Substitute for long-term tamponade, silicone oil is widely used in vitreoretinal surgery to treat retinal detachment with proliferative vitreoretinopathy and some internal reconstruction after globe trauma.OBJECTIVES: The aim of this study was to compare the changes in visual acuity, axial length, and refraction in eyes before and after removal of intraocular silicone oil of 2 different viscosities after retinal reattachment surgery. The difference in the final anatomic success (stable retinal reattachment) rate was also assessed.METHODS: Patients with surgically reattached retinas were enrolled in this open-label, prospective, nonrandomized study. All patients underwent pars plana vitrectomy, lensectomy, scleral buckling or encircling, and epiretinal membrane dissection; silicone oil was removed after stable retinal reattachment was achieved. Refraction, axial length, final Visual acuity, and stable retinal reattachment were assessed <= 2 days prior to surgery (baseline) and <= 1 month after silicone oil removal. Refraction was measured using an autorefractometer, and axial length was measured using A-scan ultrasonography, while visual acuity was assessed using a standard Snellen chart.RESULTS: Of the 96 eyes assessed for inclusion, 89 eyes of 89 Chinese patients (mean [SD] age, 36.8 [4.3] years) were Included in the study. Forty-two eyes (47.2%) were Filled with 3700-centistoke (6) silicone oil and 47 (52.8%) were filled with 5000-cS silicone oil. The mean interval between instillation and removal of the silicone oil was similar between the 3700-cS and 5000-cS groups (5.37 vs 5.10 months, respectively). The mean changes in visual acuity from before surgery to after removal of the silicone oil in the 3700-cS and 5000-cS groups were not significantly different (13/100 vs 15/100). The mean increase in axial length was also not significantly different in the 3700-cS group compared with the 5000-cS group (11.92 [1.97] vs 12.33 [1.28] mm). Mean decrease in refraction was significantly lower in the 3700-cS group compared with the 5000-cS group (5.80 [1.51] vs 6.88 [2.31] diopters; t = 2.57, P < 0.05). The anatomic success rate was 92.9% (39/42 patients) in the 3700-cS group and 91.5% (43/47) in the 5000-cS group.CONCLUSIONS: A statistically significant decrease in refraction from baseline was found in the 3700-cS group compared with the 5000-cS group in these Chinese patients who underwent instillation and removal of silicone oil after retinal reattachment surgery. There were no other statistically significant differences between the 2 groups. (Curr Ther Res Clin Exp. 2009;70:221-227) (C) 2009 Excerpta Medica Inc.