Frequency-resolved Raman for Transient Thermal Probing and Thermal Diffusivity Measurement.

Tianyu Wang,Shen Xu,David H. Hurley,Yanan Yue,Xinwei Wang
DOI: https://doi.org/10.1364/ol.41.000080
IF: 3.6
2015-01-01
Optics Letters
Abstract:A new transient Raman thermal probing technique, frequency-resolved Raman (FR-Raman), is developed for probing the transient thermal response of materials and measuring their thermal diffusivity. The FR-Raman uses an amplitude-modulated square-wave laser for simultaneous material heating and Raman excitation. The evolution profile of Raman properties: intensity, Raman wavenumber, and emission, against frequency are reconstructed and used for fitting to determine the thermal diffusivity. A microscale silicon (Si) cantilever is used to investigate the capacity of this new technique. The thermal diffusivity is determined as 9.57×10-5  m2/s, 11.00×10-5  m2/s, and 9.02×10-5  m2/s via fitting Raman intensity, wavenumber, and total Raman emission, respectively. The results agree well with literature data. The FR-Raman provides a novel way for transient thermal probing with very high temporal resolution and micrometer-scale spatial resolution.
What problem does this paper attempt to address?