Ultrasonic Measurement of Clamping Force for Injection Molding Machine

Yao Zhao,Peng Zhao,Jianfeng Zhang,Junye Huang,Neng Xia,Jianzhong Fu
DOI: https://doi.org/10.1515/polyeng-2018-0268
IF: 4.2
2019-01-01
Ultrasonics
Abstract:Abstract An online and feasible clamping force measurement method is important in the injection molding process and equipment. Based on the sono-elasticity theory, an in situ clamping force measurement method using ultrasonic technology is proposed in this paper. A mathematical model is established to describe the relationship between the ultrasonic propagation time, mold thickness, and clamping force. A series of experiments are performed to verify the proposed method. Experimental findings show that the measurement results of the proposed method agree well with those of the magnetic enclosed-type clamping force tester method, with difference squares less than 2 (MPa)2 and errors bars less than 0.7 MPa. The ultrasonic method can be applied in molds of different thickness, injection molding machines of different clamping scales, and large-scale injection cycles. The proposed method offers advantages of being highly accurate, highly stable, simple, feasible, non-destructive, and low-cost, providing significant application prospects in the injection molding industry.
What problem does this paper attempt to address?