Magnetic Resonance Imaging Evaluation of Renal Ischaemia-Reperfusion Injury in a Rabbit Model.

Liang Pan,Jie Chen,Wei Xing,Zhaoyu Xing,Jinggang Zhang,Yan Peng,Zhuoli Zhang
DOI: https://doi.org/10.1113/ep086203
2017-01-01
Experimental Physiology
Abstract:The aim was to evaluate the feasibility of susceptibility-weighted imaging (SWI) as a tool to identify the changes in the renal outer medulla (OM) in a rabbit model of renal ischaemia-reperfusion injury (IRI). New Zealand rabbits were used (control group n=10; IRI group n=40). The rabbits in the IRI group were subjected to left renal artery clamping for 60min. T2-weighted (T2WI) and SWI examinations were performed at 1, 12, 24 or 48h after reperfusion (each n=10). After the examinations, the kidneys were submitted to histological evaluation. The contrast-to-noise ratio (CNR) for the left renal OM was measured using T2WI and SWI. The T2WI and SWI scores of the integrity of the renal OM were evaluated. There were significant differences between T2WI CNRs and SWI CNRs in the control group and the IRI 1, 12 and 48h time points (all P<0.05). No significant difference was found between T2WI and SWI CNRs at IRI 24h (P>0.05). The mean SWI scores of renal OM in the IRI 1 and 12h subgroups were both significantly lower than that in the control group (all P<0.05). The only significant difference in the mean T2WI scores of renal OM was observed between the control and IRI 1h groups (P<0.05). Susceptibility-weighted imaging has a significant advantage in evaluation of healthy renal OM over conventional magnetic resonance imaging, and it is a feasible non-invasive tool for imaging and evaluating changes in the renal OM after IRI.