Galvanostatic Pulse Method in Time Domain and Frequency Domain to Determine the Corrosion Status of Rebar in Concrete

Yan Pei
Abstract:The corrosion status of rebar in concrete and simulated pore solution was evaluated by using galvanostatic pulse method. A new algorithm was developed to analyze the measuring results in time domain and frequency domain. The polarization resistance R p and surface dispersion factor α of rebar in concrete can be determined. Therefore the corrosion rate and the risk of pit corrosion of rebar can be diagnosed. The corrosion mechanism was studied with the acquired impedance spectrum. It was found that both the corrosion current and α can be used to describe the corrosion status when rebar corrodes badly; but there is frequently discrepancy between the results from corrosion current and α in the critical period of depassivation. It is difficult to use the criterion of corrosion current to judge the corrosion status of rebar in very initial stage of depassivation. Otherwise it can be done to use α criterion.
Engineering,Materials Science
What problem does this paper attempt to address?