Analysis of Gavalnostatic Pulse Method in Frequency Domain Used in Corrosion Studies

YAN Peiyu,CUI Lu
DOI: https://doi.org/10.3321/j.issn:1000-0054.1999.06.035
1999-01-01
Abstract:The results got by gavalnostatic pulse method (GPM) in time domain were compared with those got by electrochemical impedance spectroscopy (EIS) in frequency domain, which is used frequently to determine the corrosion status in electrochemical research, in order to develop a fast measuring method of corrosion status of rebar in reinforced concrete. Their relationship was discussed theoretically. A formula was deduced based on Fourier transformation to establish the conversion of the result of GPM from time domain into frequency domain. It is found that the information got by GPM in t/(RC) =0 ̄5 is nearly equivalent to the information got by EIS in low frequency region. The calculating error is smaller than 4%. This is why GPM method can get enough information in a much shorter time than EIS method does.
What problem does this paper attempt to address?