Measurement and Application of Original Spectrum and Transmission Spectrum of X-ray Tube
ZHANG Cui,ZHANG Yi-hai,SHANG Hong-jie,PAN Xiao-dong,SHAO Cao-jie,YU De-yang,LUO Yan-hong,LI Gong-ping
DOI: https://doi.org/10.7538/yzk.2016.50.10.1859
2016-01-01
Abstract:Based on a COMET MXR225/22 X‐ray tube ,in two cases of big and small focuses ,the original spectra were measured at different X‐ray tube voltages by a HPGe detector .At the same time ,the initial transmission spectra were measured under small focus .On this basis ,the transmission spectra of X‐ray through several different materi‐als (Al ,Ti ,Fe and Cu) were measured .The results show that the spectra of big and small focuses can be approximately same ,the low energy side has a large proportion , and the characteristic peaks of copper ,silver ,tungsten and lead are showed in original spectrum .The low energy side of the initial transmission spectrum hardens obviously , and the proportion of the high energy side increases with X‐ray tube voltage .The char‐acteristic peak of tungsten becomes evident ,the X‐ray average energy increases ,and the maximum intensity area of the spectrum is near the 1/3 of the highest energy .The metalabsorption sheet hardens X‐ray evidently ,and the hardening effect strongly dependson its atomic number .The results are applied to the hardening correction of industrialCT ,and the quality of the reconstructed image is improved .