Thermal Dechlorination of Heavily PCB-contaminated Soils from a Sealed Site of PCB-containing Electrical Equipment

Xingbao Gao,Bingjing Ji,Qifei Huang
DOI: https://doi.org/10.1007/s11356-016-6680-7
IF: 5.8
2016-01-01
Environmental Science and Pollution Research
Abstract:A large amount of soils are contaminated by leakage of polychlorinated biphenyls (PCBs) from sealed-up PCB-containing electrical equipment in China. Thermal dechlorination of soils contaminated with PCBs at a level of 108 mg g−1 and PCB77 (3,3′,4,4′-tetrachlorobiphenyl) as a model isomer in conjunction with calcium oxide was investigated in this study. The PCB dechlorination rate improved with increased temperature and time. The highest dechlorination rate was 85.3 %, and temperature was the main influencing factor. Pentachlorobiphenyl and tetrachlorobiphenyl in soils decreased or disappeared in response to treatment at 350 and 400 °C for 4 h, while monochlorinated biphenyl and biphenyl were detected after the reaction, indicating the presence of a dechlorination/hydrogenation pathway. Discrepancy in chlorine balance was observed after low-temperature thermal dechlorination. The species of dechlorination products were identified as amorphous carbon containing a crystalline graphite plane structure and a carbonyl group-containing polymerized product, demonstrating the existence of a dechlorination/polymerization pathway. The yield of amorphous carbon and high-molecular-weight intermediates increased with heating time. The results showed that the discrepancy in chlorine balance was because of the generation of polymerized products and undetected intermediates.
What problem does this paper attempt to address?