Analysis of Cracks on the Containment of Loop Nuclear Power Stations for 60 Days

yu zhuo sun,an hai yi,jie lin,peng qiao
DOI: https://doi.org/10.4028/www.scientific.net/AMM.105-107.1056
2012-01-01
Applied Mechanics and Materials
Abstract:The relation of tensile strength, temperature stress and concrete fissure was researched firstly, then it showed the causes of late cracks on concrete by theoretical calculation, the result provided a simple theoretical calculation method to avoid concrete fissure. The construction methods to control the fissure was proposed: early strengthening cooling, managing maximum temperature of concrete through lately heat preservation, and overtime to preserving concrete moisture for controlling the late strain on mass concrete. This research has a great significance for controlling the fissure.
What problem does this paper attempt to address?