Analysis of Cause and Treatment of Cracks on Parapets of the Main Intake Structures of the "635" Water Conservancy Project

Li Xin,Shi Kebin
DOI: https://doi.org/10.3969/j.issn.0559-9342.2006.03.008
2006-01-01
Abstract:In this paper, The cause of crack on parapets of the intake structures of the main intake of "635" water conservancy project was analyzed, which suggested that the most of cracks are temperature and construction joints. Through checks conducted on the reinforced concrete structures, the structures were found were unable to stand cracking. The lack of longitudinal reinforcement is also a cause for development of cracks. We adopted the technique of "blocking in foreside and draining on back" and used the new material-carbon fibre. It has effectively improved the crack control in the parapets and achieved ideal results in reinforcement in the project.
What problem does this paper attempt to address?