Column tests of dodecagonal section double skin concrete-filled steel tubes

ju chen,yingying ni,weiliang jin
DOI: https://doi.org/10.1016/j.tws.2014.11.013
IF: 5.881
2015-01-01
Thin-Walled Structures
Abstract:A series of tests on dodecagonal section double skin concrete-filled steel columns (DCS) were carried out in this study. Column specimens having different lengths ranged from 1000mm to 3500mm were tested. The behavior and strengths of dodecagonal section double skin concrete-filled steel columns were investigated. In addition, local bucking of inner and outer steel tubes were also investigated. Material properties of the concrete and steel used in the test specimens were measured. The test strengths are compared with the design strengths calculated using the proposed methods based on current AISC Specification and Eurocode for the design of composite structural members. The suitability of design method proposed by other researcher for circular section double skin concrete-filled steel columns for dodecagonal section specimens was also evaluated.
What problem does this paper attempt to address?