Effects of Turbulence Models on Forced Convection Subcooled Boiling in Vertical Pipe

Rui Zhang,Tenglong Cong,Wenxi Tian,Suizheng Qiu,Guanghui Su
DOI: https://doi.org/10.1016/j.anucene.2015.01.039
IF: 1.9
2015-01-01
Annals of Nuclear Energy
Abstract:In this study, a two-fluid model coupled with wall boiling model was adopted to investigate two-phase forced convection subcooled boiling process in a vertical heated pipe based on FLUENT 14.5. The influences of turbulence models (k-epsilon models and k-w models) on flow and heat transfer in pipe were studied. The performances of different turbulent models, wall functions and two-phase turbulence treatments were analyzed based on four sets of grids by comparing the calculated results with Bartolemei experimental data. The results of k-epsilon models showed better agreement with experimental data than these of k-w models. The Dispersed and Per Phase treatments for two-phase turbulence parameters performed no better than the Mixture treatment. The enhanced wall function could not cope the situation for grid with near-wall Y-plus near to 1. k-epsilon models with appropriate mesh size performed excellent in predicting subcooled boiling in vertical channel. This work can be referred for choosing turbulence model when analyzing subcooled boiling by CFD methodology. (C) 2015 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?