Imaging the Interphase of Carbon Fiber Composites Using Transmission Electron Microscopy: Preparations by Focused Ion Beam, Ion Beam Etching, and Ultramicrotomy

Wu Qing,Li Min,Gu Yizhuo,Wang Shaokai,Zhang Zuoguang
DOI: https://doi.org/10.1016/j.cja.2015.05.005
2015-01-01
Abstract:Three sample preparation techniques, focused ion beam (FIB), ion beam (IB) etching, and ultramicrotomy (UM) were used in comparison to analyze the interphase of carbon fiber/epoxy composites using transmission electron microscopy. An intact interphase with a relatively uniform thickness was obtained by FIB, and detailed chemical analysis of the interphase was investigated by electron energy loss spectroscopy. It shows that the interphase region is 200 nm wide with an increasing oxygen-to-carbon ratio from 10% to 19% and an almost constant nitrogen-to-carbon ratio of about 3%. However, gallium implantation of FIB tends to hinder fine structure analysis of the interphase. For IB etching, the interphase region is observed with transition morphology from amorphous resin to nano-crystalline carbon fiber, but the uneven sample thickness brings difficulty for quantitative chemical analysis. Moreover, UM tends to cause damage and/or deformation on the interphase. These results are meaningful for in-depth understanding on the interphase characteristic of carbon fiber composites.
What problem does this paper attempt to address?