All-optical Magnetic Recording and Its Thermal Issues

J. M. Li,L. P. Shi,G. Q. Yuan,K. G. Lim,G. Vienne,K. Eason,J. Zhang,T. C. Chong
DOI: https://doi.org/10.1117/12.859228
2010-01-01
Abstract:This work presents a thermal analysis that explains experimental observation in all-optical magnetic recording (AOMR). An integrated model is used to describe thermal processes at different time scales in AOMR. The formation of magnetic marks is discussed and implemented by developing a simulator based on 3-dimensional finite element method (FEM). The simulator is able to carry out thermal analysis of the thin film media and is a useful tool for design of AOMR media structure, especially for the thermal sink layer.
What problem does this paper attempt to address?