Inverse Charge Constant On-Time Control With Ultrafast Transient Performance
Syed Bari,Qiang Li,Fred C. Lee
DOI: https://doi.org/10.1109/jestpe.2020.2973151
IF: 5.462
2021-02-01
IEEE Journal of Emerging and Selected Topics in Power Electronics
Abstract:At the present time, current-mode constant on-time (CMCOT) control is widely used in voltage regulators (VRs) for higher light-load efficiency, higher bandwidth, and a simpler compensation network. In today's VRs, a high load step with a very high slew rate is a very common requirement in microprocessor or memory applications. One issue of this ripple-based CMCOT control is the transient response limitation at load step-up and step-down, because of its fixed $T_{mathrm{scriptscriptstyle ON}}$ time operation. In the heavy load step-up transient, the inductor current increment becomes limited by the on-time ( $T_{mathrm{scriptscriptstyle ON}}$ ) and minimum off-time ( $T_{mathrm{scriptscriptstyle OFF}_{}{mathrm{ MIN}}}$ ) ratio in each cycle, which can create large undershoot at the output. On the other hand, in the load step-down case, if a load change occurs at the beginning of the $T_{mathrm{scriptscriptstyle ON}}$ , then the decrement of the inductor current will be delayed by the fixed $T_{mathrm{scriptscriptstyle ON}}$ width, which can create a large overshoot at output. For the multiphase operation case, this ripple-based CMCOT control fails to operate at the ripple cancellation point where the inductor current ripple becomes zero. The state-of-the-art controllers add various nonlinear controls to the system to solve these issues; however, they are essentially difficult to optimize for different steady-state and transient conditions. In this article, a new concept called 'inverse charge constant on-time' (IQCOT) control is prop-sed, to improve the transient performance in CMCOT, by naturally increasing or decreasing the $T_{mathrm{scriptscriptstyle ON}}$ time in the load step-up or step-down transient without adding any nonlinear control. As this $T_{mathrm{scriptscriptstyle ON}}$ change is adaptive to the transient requirement, an optimized response is inherently provided, and hence, does not require any external adjustment. In a multiphase operation, IQCOT control can operate seamlessly at the ripple cancellation point. The proposed IQCOT control's fast and optimized transient response, with higher light-load efficiency, makes it a perfect control candidate for today's VR applications. Simulation and test results with a VR platform are also presented in this article to verify the benefits of the proposed control.
engineering, electrical & electronic